Products

Stand Alone Incubator

Walk-in Stability / Humidity Chember

Technical Specifications

 

INCUBATOR COOLING & HEATING

 Temperature Range: 20°C to 60°C Accuracy :< ± 0.2°C Uniformity :< ± 1.0°C*

 

INCUBATOR HEATING

Temperature Range : 10°C above ambient to 60°C Accuracy :< ± 0.2°C Uniformity : < ± 1.0°C*
 
 

Cooling & Heating

Models Cap. in liters Internal size in mm External size in mm  Tray Qty. Tray size in mm Connected load
AO/I-15 150 500Wx400Dx750H 625Wx860Dx1350H 2 405Wx400Dx30H 1.25 KW
AO/I-25 250 700Wx400Dx900H 825Wx860Dx1500H 2 605Wx400Dx30H 1.25 KW
AO/I-40 400 700Wx500Dx1150H 825Wx960Dx1750H 3 605Wx500Dx30H 1.25 KW
AO/I-50 500 700Wx600Dx1200H 825Wx1060Dx1800H 3 605Wx600Dx30H 1.25 KW
AO/I-60 600 700Wx600Dx1450H 825Wx1060Dx2050H 3 605Wx600Dx30H 1.25 KW
AO/I-80 800 700Wx800Dx1450H 825Wx1260Dx2050H 4 605Wx800Dx30H 1.5 KW
 AO/I-100 1000 830Wx830Dx1450H 955Wx1290Dx2050H 4 735Wx830Dx30H 1.5 KW

Heating 

Models Cap. in liters Internal size in mm External size in mm  Tray Qty. Tray size in mm Connected load
AO/I-15 150 500Wx400Dx750H 625Wx860Dx1350H 2 405Wx400Dx30H 0.75 KW
AO/I-25 250 700Wx400Dx900H 825Wx860Dx1500H 2 605Wx400Dx30H 0.75 KW
AO/I-40 400 700Wx500Dx1150H 825Wx960Dx1750H 3 605Wx500Dx30H 0.75 KW
AO/I-50 500 700Wx600Dx1200H 825Wx1060Dx1800H 3 605Wx600Dx30H 0.75 KW
AO/I-60 600 700Wx600Dx1450H 825Wx1060Dx2050H 3 605Wx600Dx30H 0.75 KW
AO/I-80 800 700Wx800Dx1450H 825Wx1260Dx2050H 4 605Wx800Dx30H 1 KW
 AO/I-100 1000 830Wx830Dx1450H 955Wx1290Dx2050H 4 735Wx830Dx30H 1 KW

* Measured with high accuracy data-logger at sample storage area with standard Set Point

Standard Chamber Features & Provisions:

  1. Ergonomically designed Control Panel.
  2. Ferrule printed wiring.
  3. Advanced PLC Program with built in processor-based Auto Tuning.
  4. 4.3” HMI Color LED Display.
  5. Built in Redundancy & Safety.
  6. Advanced High Accuracy “Transmitter Sensors” with output of 4-20 mA.
  1. Efficient, Reliable, Time tested & Trustworthy Refrigeration Design.
  2. Built in redundancy with PLC based Auto Change Over during power outage &/or component failure (Compressor)
  3. PLC Controlled “U” Shaped SS Air Heater Banks.

 

Stand Alone Incubator:

INCUBATOR (COOLING AND HEATING)

Incubator Is a device in which incubation process is done, an enclosure conditioned to a predetermined temperature to provide and maintaining an artificially created optimal conditions for growth of microbial culture.

every organism has an incubation period for its growth and development. If incubation is not provided it will result in degenerated the growth of an organism, therefore incubation is an important aspect for the proper growth and development.

Incubation is process -a period of time in which temperature and other environmental variables are provided at a desired temperature level for the growth and development of microbial culture.

Incubator those works at low temperature are used for “incubation” of biochemical reactions

Industries like pharmaceutical, research laboratories, agriculture, food & beverages requires a Cooling Incubators for their testing purposes.

Allyone’s top of the line Cooling Incubators are the most preferred choice to maintain accurate temperature & its uniformity throughout the chamber where high degree of constant temperature accuracy is required.

Incubators are mainly used for the growth & storage of bacterial cultures, Media Preparation, gentle incubation & conditioning and other purposes.  

INCUBATOR HEATING:

Incubator (Heating) are also known commonly as Bacteriological incubator:

This type of incubator is used majorly in laboratories mainly for the growth of bacterial cultures. it has a simple mechanism which maintains a constant set temperature as per the requirement. Accurate temperature maintained in the chamber is displayed on the display of incubator.

Most of the incubators are programmable and can be set as per the requirement. These types of incubators comes only with a heating system which maintains the temperature for growth of bacteria. These incubators are affected by temperature of surrounding environment so the prescribed set point is 10°C above ambient temperature hence no cooling system is required or present in these chambers.

 

 

 


ALLYONE ENVIRONMENTAL TECHNOLOGIES INDIA PVT LTD

Enquiry